127 Photos
North las vegas, NV
3 112 h
WLHZ1476KZC041454
Loading...
Ce lot est protégé par l’assurance IronClad
Achetez en toute confiance en sachant que ce lot a fait l’objet d’une inspection complète par un inspecteur qualifié.
Numéro d’identification
#12734464
Livré
Non
Année
2015
Fabricant
Modèle
Type d’actif
Numéro de série ou VIN
WLHZ1476KZC041454
Caractéristiques
Air Conditioner, Control Pattern Changer, Cab Screens, Rear View Camera, 2017 US EPA Label, Requires Diesel Exhaust Fluid, 9 ft 6 in Stick, Auxiliary Hydraulic Plumbing, Stick Check Valve, Boom Check Valves, 29.6 in Triple Grouser Track Shoes, Hydraulic Quick Coupler, 60 in Digging Bucket, Auto Lube
Remarques
LOCATED-IN-LAS-VEGAS-NV
Image, coin avant gauche
Image, coin arrière gauche
Image, coin arrière droit
Image, coin avant droit
Numéro de série/Numéro d'identification du véhicule automobile
WLHZ1476KZC041454
Hour Meter / Odometer
3112 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Peinture
Condition de la plaque métallique (fibre de verre)
Marches/échelles
Poignées
Éclairage extérieur fonctionnel
Operational
Vitres de cabine
Réveil-portefeuille
Operational
Klaxon
Operational
Ceintures de sécurité
Operational
Levier de verrouillage des gouvernes
Operational
Swing Brake
Operational
Current Safety Manual
Current Operator/Maintenance Manual
Sièges/accoudoirs
Miroirs
Steering Controls
Commandes hydrauliques
Auxiliary Hydraulic Control
Commandes de transmission
Dash Console
Engine Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Feux d'avertissement du moteur
Operational
Jauges
Operational
Air Conditioner
Operational
Heater
Operational
Vérification de fonctions limitée
The main components are in place and operational as noted.
Engine
2017 US EPA Label, Requires Diesel Exhaust Fluid
Emission Label
A/C Compressor
Operational
Blow-by (subjective visual observation)
Minor
Démarreur
Operational
Système d'échappement
Radiateur
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
The engine started and ran.
Left Drive Motor
Right Drive Motor
Left Final Drive
Right Final Drive
Vérification de fonction limitée
The drivetrain was operational.
Pompes (hydrauliques)
Soupapes
Réservoir hydraulique
Hydraulic Control Pattern Changer
Tuyaux (hydrauliques)
Seepage
Auxiliary Hydraulic Plumbing
Not operationally checked, End of stick, Seepage
Moteur pivotant
Pivot central hydraulique
Vérins de levage de bras
Seepage
Stick Cylinder
Dripping leak
Vérin de godet
Seepage
Vérification de fonction limitée
The hydraulic system was operational.
Condition du bras
Dented on the bottom
Condition du levier
Broche et douilles de la base du bras
Broche et douilles Levier à bras
Axes et bagues de bras d'attelage
Roulements de plaque tournante
Revêtements inférieurs
Vérification de fonction limitée (chargeuse-pelleteuse)
The main components were operational with damage as noted.
Left Roller Frame
Left Track Tensioner
Not tested
Left Track Shoes
Left Grouser Height
37 mm
Left Track Links
Left Carrier Rollers
Left Track Rollers
Left Idler
Left Sprocket
Right Roller Frame
Right Track Tensioner
Not tested
Right Track Shoes
Right Grouser Height
37 mm
Right Track Links
Right Carrier Rollers
Right Track Rollers
Right Idler
Right Sprocket
Condition de la pelle hydraulique
Cutting Edge / Teeth / Adapters
Attache rapide
Operational
Oil Sample Analysis
engine | hydraulic | |
---|---|---|
date of analysis | Dec 06, 2024 | Dec 06, 2024 |
Silicon | 3.37 PPM | 1.63 PPM |
Tin | 0.17 PPM | 1.18 PPM |
Silver | 0 PPM | 0 PPM |
Aluminum | 0.47 PPM | 1.37 PPM |
Chromium | 0 PPM | 0.3 PPM |
Lead | 0.03 PPM | 0.98 PPM |
Copper | 0.07 PPM | 10.54 PPM |
Nickel | 0.56 PPM | 0.74 PPM |
Iron | 1.6 PPM | 7.03 PPM |
Glycol | NEG | N/A |
Water | NEG | N/A |
Fuel | <5% | <5% |
Les articles doivent être payés en entier d’ici le samedi 5 juillet 2025. Des frais de retard seront appliqués après la date d’échéance.
PaiementsSoumettez votre article à VeriTread et recevez des devis de fret gratuitement et sans obligation.
Les Informations détaillées de l’équipement sont d’une portée limitée, et les Encans Ritchie Bros. n’ont inspecté aucun autre aspect ou composant de l’équipement que ceux présentés expressément. Sauf indication précise, nous n’offrons aucune représentation ou garantie, officielle ou implicite, sur l’équipement ou ses composants, sans aucune limite de représentation ou de garantie en ce qui concerne la fonctionnalité, la conformité à toute norme de sécurité ou l’exigence de toute autorité ou agence de régulation en vigueur, l’adaptation à un quelconque usage, ou la valeur commerciale. Il vous est fortement conseillé d’effectuer votre propre inspection détaillée de l’équipement avant d’enchérir.
L’équipement n’est pas testé sous chargement ni opéré dans tous les rapports disponibles. Nous n’offrons aucune représentation ou garantie sur le fait que l’équipement fonctionne conformément aux spécifications des fabricants. Aucune inspection n’a été effectuée quant à un autre aspect fonctionnel que ceux expressément mentionnés précédemment. Seules quelques photos ont été fournies pour les composants individuels de l’équipement et elles ne peuvent pas être considérées comme des éléments indicateurs de la condition de l’équipement dans son ensemble.
Les dimensions données ne sont qu’une estimation. Les dimensions réelles pour le chargement peuvent varier en fonction de la hauteur du camion/remorque et de la configuration/position de la machine une fois chargée. L’acheteur est responsable de la prise de mesures de toutes les charges avant de quitter le site d’enchères, et ce, afin de s’assurer que la charge peut être transportée en toute sécurité. Toutes les dimensions doivent être vérifiées par l’acheteur. Veuillez ne pas vous fier à ces dimensions pour le transport.